<LOGO>
FM Transmitter Measurement Report
Created: 2025-05-14 15-20-18
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 58 dBuV SANDELS
Pilot RDS Phase Difference
4.6 kHz 5.2 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 66 kHz 14476 6,1826
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,7 dBr 4,38 dBr 5,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7 MHz -
FM Scope Max at: 66 kHz MIN: 9 kHz % above 76 kHz: 6,1826 Acquired: 2025/05/14 15.19.14 Total samples: 14476 Equivalent time: 0:12:03 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 5,6 dBr MIN: 2,7 dBr AVE: 4,38 dBr % above 12,2 dBr: 0,0 Last value: 4,6 dBr (2025/05/14 15.19.14) 15.06 15.08 15.10 15.12 15.14 15.16 15.18 0 2 4 6 Pm [dBr]